DAkkS-accredited calibration to DIN EN ISO/IEC 17025

Whether at our laboratory in Dortmund or directly on site at your premises – we calibrate your measuring and test equipment with traceability to the SI system of units, within a maximum of 10 working days by appointment.

Accredited to DIN EN ISO/IEC 17025:2018
Metrologically traceable results
Internationally recognised under the ILAC MRA
Calibration within max. 10 working days
Reliable & traceable

The journey of your measuring and test equipment

From scheduled order to calibration certificate: a well-established process with clearly defined steps, so you can quickly resume work with your calibrated equipment.

1

Scheduled order & delivery

Quantity and delivery date are agreed in advance, and suitable laboratory capacity is reserved.

2

Goods receipt & inspection

Visual inspection, allocation and clarification of whether accredited or in-house calibration is required.

3

Calibration

At our laboratory in Dortmund or directly on site at your premises – using accredited or in-house procedures.

4

Evaluation & calibration certificate

Evaluation of the measurement results according to the level of confidence, followed by issuance of the calibration certificate.

5

Return shipment

Secure packaging and return shipment of your measuring and test equipment – within a maximum of 10 working days.

DAkkS accreditation · D‑K‑20476‑01‑00

Accredited quantities & scope of accreditation

The official scope of our accreditation to DIN EN ISO/IEC 17025:2018, valid from May 7, 2025. We also offer accredited on-site calibration for a subset of these quantities directly at your premises.

For hardness and ultrasonic testing equipment, we are accredited with a flexible scope under Category III (in accordance with EA‑2/15). This allows us to update the underlying standards without prior approval from DAkkS. We maintain the current status in a publicly available list of procedures – see "Documents" below.

Illuminance meters

Photometry, standard illuminant A
DAkkS-accreditedLaboratory only
2–3000 lx
C‑TEC‑KA_19:2022
2.5 %
Based on DIN EN ISO 3059, ASTM E2297, BS 667 Annex B2.2. Standard measurement points: 20 · 1000 · 1800 lx.

Irradiance meters

Radiometry, UV-A 365 nm
DAkkS-accreditedLaboratory only
100–6000 µW/cm²
C‑TEC‑KA_18:2022
11.0 %
Based on DIN EN ISO 3059, CIE 220, ASTM E2297. Standard measurement points: 300 · 1000 · 5000 µW/cm².

Ultrasonic testing equipment

All parameters identical in laboratory and on site · flexible accreditation, Category III
DAkkS-accreditedLaboratory & on site
Parameter Measuring range Procedure Expanded uncertainty
Gain linearity 1–110 dB DIN EN ISO 22232‑1:2021, group 2 0.18 dB
Vertical screen axis 0–100 % FSH DIN EN ISO 22232‑1:2021, group 2 0.58 % FSH
Accuracy of the calibrated attenuator 1–110 dB DIN EN 12668‑1:2010 (withdrawn), group 2 0.18 dB
Vertical axis linearity 0–100 % FSH DIN EN 12668‑1:2010 (withdrawn), group 2 0.58 % FSH
Time axis linearity 2 ns–2 ms DIN EN 12668‑1:2010 (withdrawn), group 2 10 ns / 0.080 % FSW
FSH = Full Screen Height, FSW = Full Screen Width. DIN EN 12668‑1:2010 has been withdrawn but continues to be offered within our accredited scope at customer request – some customers explicitly require it.

Ultrasonic wall thickness gauges

Length (wall thickness) · flexible accreditation, Category III
DAkkS-accreditedLaboratory & on site
Measuring range Procedure Expanded uncertainty
1–100 mm DIN EN 15317:2014, group 2 0.020 mm
1–100 mm DIN EN ISO 16831:2025 0.020 mm
Both procedures are available on an equal basis within our accredited scope – depending on the test instrument and customer requirements.

Magnetic field strength meters

DC field
DAkkS-accreditedLaboratory & on site
1–7 kA/m
C‑TEC‑KA 5.4_09:2018
1.1 % laboratory · 1.5 % on site
Based on DIN EN ISO 9934‑3:2015. Standard measurement points: ±1.0 · ±4.0 · ±7.0 kA/m (6 measurement points).

Magnetic field strength meters

AC field, 50 Hz
DAkkS-accreditedLaboratory & on site
1–7 kA/m
C‑TEC‑KA 5.4_09:2018
1.5 % laboratory · 2.0 % on site
Based on DIN EN ISO 9934‑3:2015. Standard measurement points: 1.5 · 4.0 · 7.0 kA/m.

We also calibrate measurement points outside the accredited range, from 0.2 to 8.0 kA/m – indicated accordingly on the calibration certificate.

Hardness testers (UCI method)

HV 1 / HV 5 / HV 10 · flexible accreditation, Category III
DAkkS-accreditedLaboratory & on site
20–900 HV
DIN 50159‑02:2022
1.5 · UCRM
Indirect calibration using hardness reference blocks.

Hardness testers (Leeb method)

Impact body D · flexible accreditation, Category III
DAkkS-accreditedLaboratory & on site
300–900 HLD
DIN EN ISO 16859‑2:2016
1.5 · UCRM
Indirect calibration using hardness reference blocks, impact body D.

UCRM = calibration uncertainty of the hardness reference block used. The standard measurement points listed are our most common test points – on request, we also calibrate at other points within the accredited measuring range. Measurement points outside our accreditation scope are also available on request as in-house calibration. The full, flexible accreditation scope with all standards referenced can be found in the certificate annexes below. Our non-accredited range of services, including further on-site services, can be found under Service.

Non-accredited services

In-house calibration & inspection

We perform in-house calibrations and functional inspections using traceable reference material – according to our own and international procedures, at our laboratory and, for many devices, on site as well.

In-house calibrations

Traceable, using certified reference material
Not accredited
Procedure / calibration item Applicable standards and regulations
DensitometerASTM E1079‑16
Coating thickness (non-magnetic coatings on magnetic base metals)DIN EN ISO 2178:2016
Coating thickness (non-conductive coatings on non-magnetic metallic base materials)DIN EN ISO 2360:2004
Reference block No. 1 / calibration block K1DIN EN ISO 2400, DIN EN ISO 16946
Calibration block No. 2 / K2DIN EN ISO 7963, DIN EN ISO 16946
Step wedgeDIN EN ISO 16946
Reference block 2DIN EN ISO 3452‑3
Luminance meterBS 667:2005 Annex B 2.2
Ultrasonic equipment (analog, digital)DIN EN 12668‑1:2010 (withdrawn), DIN EN ISO 22232‑1:2021
Phased array equipment (in-house portion)DIN EN 18563‑3:2024
Crack depth gaugeDIN EN ISO 15548‑1
For phased array equipment, the conventional portion can be calibrated under accreditation (see ultrasonic testing equipment above); the phased array portion is performed as in-house calibration based on DIN EN 18563‑3, sections 9.3 and 9.4.

Inspections

Functional inspection to confirm correct operation
Not accredited
Procedure / inspection item Applicable standards and regulations
Film viewer (viewing devices for industrial radiography)DIN EN ISO 5580:2024, ASTM E1390:2021
Yoke magnetDIN EN ISO 9934‑3:2015, DGUV V3
Magnetic test benchDIN EN ISO 9934‑3:2015, DGUV V3
Magnetizing deviceDIN EN ISO 9934‑3:2015, DGUV V3
Irradiance lamp (UV lamp)DIN EN ISO 9934‑3:2015
Reference block 1 (MTU test disc)DIN EN ISO 9934‑2:2015
Reference block type 1 / type 2DIN EN ISO 3452‑3
FLUXA test blockDIN EN ISO 3059:2002
Eddy current deviceDIN EN ISO 15548‑3, DGUV V3

On-site calibration – we come to you!

Downtime and immobility: two key arguments for on-site calibration
Manufacturer-independent
Low measurement uncertainty
On-site adjustments/repairs possible
Minimal effort on your part and fast return to service of your measuring equipment

In-house calibration certificates do not meet the requirements of the EA MLA. Detailed information on our on-site services can be found under Service.

Missed the deadline? No problem.

Coordinate quantity and delivery date of your measuring and test equipment with us in advance – we reserve the appropriate laboratory capacity. Calibration within a maximum of 10 working days.

Request an appointment →
📍